KNEE
- GENUTECH DCF Surgical Technique (ESP)
- GENUTECH DCF Surgical Technique (ENG)
- GENUTECH DCF Express Surgical Technique (ESP)
- GENUTECH DCF Surgery Video (ESP)
- GENUTECH CCK Surgical Technique (ESP)
- GENUTECH CCK Surgical Technique (ENG)
- GENUTECH CCK Surgery Video (ESP)
- KNEE ARTHROPLASTY Patients Guide (ESP)
HIP
- AUSTIN MOORE Surgical Technique (ESP)
- AUSTIN MOORE Surgical Technique (ENG)
- THOMPSON Reference catalogue (ESP)
- THOMPSON Reference catalogue (ENG)
- FEMORAL HEAD Reference catalogue (ESP)
- FEMORAL HEADS Reference catalogue (ENG)
- BIARTICULAR HEAD Surgical Technique (ESP)
- BIARTICULAR HEAD Surgical Technique (ENG)
- ENDOCEPHALIC HEAD Reference catalogue (ESP)
- ENDOCEPHALIC HEAD Reference catalogue (ENG)
- MÜLLER CUP Surgical Technique (ESP)
- MÜLLER CUP Surgical Technique (ENG)
- QUARTER CUP Surgical Technique (ESP)
- QUARTER CUP Surgical Technique (ENG)
- SELF-LOCKING STEMS Surgical Technique (ESP)
- KAREY PRIMARY STEMS Surgical Technique (ESP)
- KAREY REVISION STEMS Surgical Technique (ESP)
- KAREY PRIMARY STEMS Surgical Technique (ENG)
- KAREY REVISION STEMS Surgical Technique (ENG)
- HIP ARTHROPLASTY Patients guide (ESP)
TRAUMA
OTHERS
- PULSE LAVAGE Reference Catalogue (ESP)
- PULSE LAVAGE Reference catalogue (ENG)
- BONE CEMENT MIXING BOWL Catalogue (ESP)
- BONE CEMENT MIXING BOWL Catalogue (ENG)
- C-PLUG Reference Catalogue (ESP)
- C-PLUG Reference catalogue (ENG)
- BONE CEMENT GUN Catalogue (ESP)
- MIXING SYRINGE Catalogue (ENG)
- BONE CEMENT Reference Catalogue (ESP)
- BONE CEMENT Reference Catalogue (ENG)
- ORCEM BONE CEMENT 1&3 Reference Catalogue (ENG)
- ORCEM BONE CEMENT 1G&3G Reference Catalogue (ENG)
- SURGINIBS Bone Substitute Catalogue (ESP)
- SURGINIBS Bone Substitute Catalogue (ENG)
- SURGIBONE Bone Filling Catalogue (ESP)
- Catalogue bone filling SURGIBONE (ENG)
Karey Stem Characteristics:
The design Karey Primary Stems Surgival provides an ideal combination of resistance and fixation by minimising the geometry, offering a concept that is respectful of the patient’s anatomy.
The progressive trapezoidal geometry enables optimal adaptation of the stem and both anti-translational and anti-rotational fixation that provides perfect primary stability while preventing the hip prosthesis from sinking.
Specifications
- Standard Offset y High Offset.
- 12/14 taper.
- 135º cervical–diaphyseal angle and 125º in Karey HA.
- Available in cemented and cementless versions.
Cementless Karey HA
- Made from Titanium Alloy (Ti6Al4V).
- Hydroxyapatite spray coating (130 µm) that provides a porous surface with excellent biocompatibility and generates an ideal structure for bone growth.
- Stems available with and without collars (limits implant subsidence and migration).
- Triple wedge design: The trapezoidal shape in the sagittal and frontal planes offers enhanced primary stability and prevents prosthesis sinking. The size of the distal part is progressively reduced to decrease implant rigidity and improve contact with the cancellous bone (secondary stability).
- Metaphyseal semicircular macrostructures: increase the contact surface, preventing sinking and providing an antivarus effect.
- Longitudinal grooves: Increase bone–implant contact surface, preventing rotation, reducing distal rigidity with respect to the metaphyseal portion and improve diaphyseal vascularisation of the femur with the prosthetic.
- Use: Cementless
KAREY HA NO COLLAR STEM VARIANTS:


- Sizes:
ACD 135º STANDARD OFFSET: T6, T8, T9, T10, T11, T12, T13, T14, T15, T16
ACD 135º HIGH OFFSET: T9, T10, T11, T12, T13, T14, T15, T16
ACD 125º STANDARD OFFSET: T9 y T10
KAREY HA COLLAR STEM VARIANTS:


- Sizes:
ACD 135º STANDARD OFFSET: T8, T9, T10, T11, T12, T13, T14, T15, T16
ACD 135º HIGH OFFSET: T9, T10, T11, T12, T13, T14, T15, T16
ACD 125º STANDARD OFFSET: T9, T10, T11, T12, T13, T14, T15, T16
ACD 125º HIGH OFFSET: T9, T10, T11, T12, T13, T14, T15, T16
Cemented Karey C
- Made from High Nitrogen Stainless Steel (ISO 5832- 9).
-
Triple wedge design: The trapezoidal shape in the sagittal and frontal planes offers enhanced primary stability and prevents prosthesis sinking.
-
Polished surface with rounded edges: Ensure correct adhesion to the cement, preventing the concentration of tension.
-
Fine conical distal tip: Prevents diaphyseal locking and provides a construction with distal flexibility so as to not compromise the cemented fixation.
- Stems also available in sizes 11 to 16 with centraliser orifice.
- Use: Cemented


- Sizes:
ACD 135º STANDARD OFFSET: T8, T9, T10, T11, T12, T13, T14, T15, T16 (option with centraliser orifice from T11 to T16)
ACD 135º HIGH OFFSET: T9, T10, T11, T12, T13, T14, T15, T16 (option with centraliser orifice from T11 to T16)