RADLOCK Radial locking plates

Excellent functional results and early mobility for the treatment of  unstable radius fractures.

RadLock characteristics:

RadLock system Surgival is a highly versatile solution for distal and proximal radius fractures. Its fixed-angle locking design enables the configuration of fixations with high angular stability, even in poor quality bone.  The large variety of plates, with carefully defined screws trajectories, provides the fragment fixation and joint support needed across a wide range of fracture patterns.

 

Specifications

  • All the implants are made of Titanium Alloy Ti6AI4VELI (ISO 5832-3/ASTM F136)
  • Fixed-angle, threaded locking hole: Multifragmentary angular stability.
  • Preformed anatomical design: The plates adapt to the anatomy of the radius, minimising the need for bending in surgery.
  • Combined holes: Compression fixation with cortical screws or internal fixation with locking screws.
  • Low profile reduced bone contact:  Prevents irritation of soft tissues, preserving bone vascularisation.
  • Progressively tapered end to facilitate minimally invasive atraumatic insertion (only in some plates).
  • Bent notches: To facilitate contouring and to prevent the threaded holes from deforming with moulding (only in some plates).

RadLock provides temporary fixation during radius fracture consolidation by means of multiple surgical approaches (volar or dorsal in distal radius and lateral in proximal radius).

The system is made up of:

VOLAR DISTAL RADIUS LOCKING PLATES

DORSAL DISTAL RADIUS LOCKING PLATES

The LOCKING PLATES for RADLOCK DISTAL RADIUS are indicated for:

  • Fixation of displaced intra-articular and extra-articular distal radius fractures
  • Correction of malunion in distal radius fractures

*Plates with right and left anatomical versions

 

PROXIMAL RADIUS LOCKING PLATES

LOCKING PLATES for PROXIMAL RADIUS are indicated for:

  • Fixation of displaced intra-articular and extra-articular proximal radius fractures
  • Fixation of multifragmentary radial neck fractures

*Plates with right and left anatomical versions

 

RADLOCK SCREW SYSTEM

Both the cortical screws and the locking screws use hexalobular technology (SixLobe) in their connection interface with the screwdrivers.

This technology optimises application of the torque, preserving connection integrity during tightening and facilitating extraction manoeuvres.

 

Lengths: The screws are available in 13 lengths (from 6 to 30 mm, with 2 mm increments)

 